Also make sure you do not place a co detector directly next to a fuel burning appliance.
Floor mount fire alarm.
The r6000 is a range of 19 rack mounted fully modular addressable fire alarm control panels available in 2 or 4 loop capacity.
Install detectors on or as near to the ceiling as possible.
Designed to be housed in either eaton s own 19 floor rack unit 39uecrack or in non eaton 19 rack units the r6000 range enables buildings to house the fire alarm control panel either in server rack or control rooms instead of mounted to the wall.
Electromagnetic door holders and releasers keep doors open until they are released by fire alarm systems remote smoke detectors or other switching devices.
Electromagnetic floor mounted fire door holders are ideally suited to applications where maximum protection is needed against vandalism or accidental damage.
Designed to be used on self closing swinging doors to automatically isolate an area when activated by fire alarm smoke detection or sprinkler systems.
Floor mounted available for single doors or two doors mounted back to back adequate space must be considered for floor mounted holder releases.
Like smoke detectors co alarms need to be tested regularly and cleaned as indicated in the manufacturer s use and care booklet.
If the unit operates off a battery test the detector weekly and replace the battery at least once a year.
In the event of a power failure they release the door to a closed position to keep the facility secure.
Mount smoke alarms high on walls or ceilings remember smoke rises.
Wall mounted alarms should be installed not more than 12 inches away from the ceiling to the top of the alarm.
It features a rugged cast aluminium housing a holding electromagnet with integral anti residual ejection pin and a manual release switch.
They provide a high holding force.
In rooms without a fuel burning appliance or an open fire put the co alarm close to the breathing zone.
If you have ceilings that are pitched install the alarm within 3 feet of the peak but not within the apex of the peak four inches down from the peak.
Mount it between 3 feet about 1 m and 10 feet about 3 m horizontally from the nearest edge of the potential source.
Designed for virtually any remote door release application electromagnetic door holders releases can be be tripped by an alarm or smoke detector or triggered by a remote switch.
Many smoke detectors are designed to mount to a ceiling but some can also be wall mounted when attaching to a ceiling isn t feasible.